Les langues disponibles

GB
Automatic Heat/Refresh Mode selection
A sensor inside your radiator monitors the temperature of the hot/cold water
supply. Another sensor measures the ambient temperature in your room.
Heat Mode is selected automatically if the water temperature rises above
the minimum Heat Mode temperature:
≥ 25ºC
Refresh Mode is selected automatically if the water temperature drops
below the maximum Refresh Mode temperature:
≤ 21ºC
Note: no action by the user is required to switch between these 2 modes:
Refresh
Mode
Note: in all cases, a minimum gap of 2ºC between water temperature
inside your appliance and ambient temperature in your room is required for
fan operation.
Fan operation logic
See Appendix
10
No fan
operation
Heat
Mode
21ºC
25ºC
Water temperature
inside the radiator

Publicité