Specifications; Important Hints; Used Symbols; Installation - Hameg Instruments HM8001-2 Manuel D'utilisation

Masquer les pouces Voir aussi pour HM8001-2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technische DaTen
Technische DaTen

specificaTions

Referenztemperatur: 23 °C ±2 °C
Referenztemperatur: 23 °C ±2 °C
Valid at 23 degrees C after a 30 minute warm-up
period
General
Mainframe with power supply accomodates any
2 modules. 4 BNC connectors on rear panel for external
interconnection to each module compartment
(Option HO801)
Module supply Voltages
2 x 8 V
max. 0.5 A each
AC
2 x 5 V
max. 1 A each
DC
4 x 20 V
max. 0.5 A each
DC
Voltages:
between 5 V and 20 V are
programmable from each
module
Polarity:
optional
Power consumption per module:
max. 25 Watt
All DC voltages are electronicaly stabilized, floating
and short circuit proof.
AC test voltage to chassis:
500 V
Miscellaneous
Power switch on front panel between the two modules.
Line voltage:
115/230 V at 50 - 60 Hz
Power consumption:
max. 110 Watt
Protective system:
Safety class I (EN61010-1)
Size (W x H x D):
285 x 75 x 365 mm
Weight:
approx. 4 kg
Color:
techno-brown
Included in delivery:
Maineframe HM8001-2, Operator's manual
Optional Accessories:
HO801 BNC connectors
S p e c i f i c a t i o n s

Important hints

The operator is requested to carefully read the
following instructions and those of the mainframe
HM8001-2, to avoid any operating errors and mi-
stakes and in order to
become aquainted with
the module.
After unpacking the module,
check for any mechanical damage
or loose parts inside. Should there be any trans-
portation damage, inform the supplier immedi-
ately and do not put the module into operation.
This plug-in module is primarily intended for use
in conjunction with the Mainframe HM8001-2.
When incorporating it into other systems, the
module should only be operated with the specifi­ed
supply voltages.

Used Symbols

ATTENTION refer to manual.
DANGER High voltage.
Protective ground (earth) terminal.

Installation

If the HM8001-2 is to be stacked with other main-
frames or HAMEG Oscilloscopes, the exact posi-
tioning is only ensured by the footrests delivered
with the instrument. These should be attached
to the top of each instrument (except the upper-
most one) using the double-sided adhesive tape
provided. Insert the footrests into the appropriate
ventilation holes on top of the lower instrument
in such a way that they correspond exactly with
the positioning of the feet on the instrument to
be stacked above. Instruments stacked in a tilted
position will now be prevented from slipping. Put
Subject to change without notice
TRIPLE POWER SUPPLY HM 8040-3
FUSE
FUSE
ON/OFF
ON/OFF
OUTPUT
HAMEG
PUSH LONG
VOLTAGE
CURRENT
VOLTAGE
CURRENT
13

Publicité

Table des Matières
loading

Table des Matières