Lighting Instructions:
Starting the Heater (Ignition
1. Connect the heater to a 3-prong (grounded) power
source. If extension cord is required, it must be a 3-prong
(grounded) extension cord that is at least 6 feet long is a
minimum of 14 AWG.
2. Connect heater to a proper LP cylinder.
3. Wait five (5) minutes for any gas to clear. Smell for gas. If you
do not smell gas, go to step 4.
4. Turn gas supply ON by turning the LP cylinder valve
COUNTERCLOCKWISE to OPEN.
5. Push the power switch to ON. The fan should start running.
6. Press and hold the Gas Control Button. While it is pressed,
push the piezo ignition button on the opposite side of the
base until fuel ignities. Continue to hold the Gas Control
Button for 30 seconds.
7. If the burner doesn't stay lit, repeat lighting procedures.
– Risk of indoor air pollution and carbon
monoxide poisoning. Use heater only in well
ventilated areas.
– Refer to Safety Information on Pages 2 and 3 for
information about carbon monoxide poisoning.
– ALWAYS provide a fresh air opening in the heated
space of at least three square feet (2,800 sq. cm) for
each 100,000 BTU / Hr (29 kW). of heater output.
Provide a larger opening if more heaters are being
used.
© 2018 Pinnacle Climate Technologies Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
OPERATION (CONT.)
)

VENTILATION

CONNECTED TO A POWER SOURCE

Shutdown Instructions

To Shut Off the Heater:
1. Turn gas supply OFF by turning the LP cylinder valve
CLOCKWISE to close.
2. Continue to operate the heater until all the gas in the hose
has burned and there is no more flame.
3. Disconnect the power cord.
NOTE: Heater surface temperature must be cold before
initiating service, cleaning or storage.
DANGER
DANGER
inadequately ventilated, enclosed spaces.
Minimum Ventilation Opening Needed
8
Propane Forced Air Heater User's Manual (ST-60HB2-GFA)
CARBON
MONOXIDE
POISONING MAY
LEAD TO DEATH!
Not for use
in residential
living areas or in
60HB2-GFA
1.8 ft.
2
1670 cm
2