Pinnacle Climate Technologies Stanley ST-60HB2-GFA Manuel De L'utilisateur Et Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
Pre-Lighting Instructions:
WARNING
have been thoroughly trained in accepted LP
gas industry procedures. Failure to follow these
instructions may result in explosion, fire, severe
personal injury, or death.
Connecting the LP Cylinder
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE
FIRST FILLING.
Turn heater gas valve switch button and LP cylinder valve
to OFF position.
LP cylinder valve equipped with old style fitting has LEFT
HANDED THREADS. Turn fitting CLOCKWISE to loosen.
Protect this fitting when disconnected from LP cylinder.
Have your LP cylinder filled by your local propane gas
supplier.
Some LP cylinders have a bleed-OFF valve. This valve
should be inspected for leaks after each filling of the LP
cylinder. Turn the valve clockwise to close.
Fasten full propane tank and connect proper fitting to
LP cylinder valve by turning COUNTER-CLOCKWISE (see
Figure 2 and 3).
Supply Valve
Regulator
Hose
Figure 2
© 2018 Pinnacle Climate Technologies Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
OPERATION (CONT.)
The disconnected
tank must never be
stored in a building,
garage, or any other
enclosed area.
Purging and filling
of the LP cylinders
must be performed
by personnel who
Propane Tank
CONNECTED TO A POWER SOURCE
With heater gas valve switch button still in OFF position
turn ON the LP cylinder valve and check for leaks with
soap solution (see below).
Checking For Leaks
To check for leaks, make up a 50/50 solution of dish soap
and water. Apply this solution to all gas connections. If
bubbles appear, there is a leak. If a leak is found, turn off
the gas supply and re-connect the leaking connection.
If the leak persists after several tries, contact Pinnacle
Climate Technologies at 800-641-6996.
The installation of this heater must meet all local codes
and / or gas utility requirements. In the absence of local
codes, the National Fuel Code ANSI Z223.1 / NFPA 54
should be followed.
The minimum clearances to any combustible construction
materials must be maintained at all times (see Page 3).
Inspect the heater before each use, and at least annually
by a qualified service person.
Figure 3
7
Propane Forced Air Heater User's Manual (ST-60HB2-GFA)
Inlet
Connector
Hose

Publicité

Table des Matières
loading

Table des Matières