WARNING
WARNING
with a 3-prong (grounding) plug for your
protection against shock hazard and should be
plugged directly into a properly grounded 3-prong
receptacle.
WARNING
ALWAYS install the heater so that it is not directly exposed to water
spray, rain, dripping water, or wind.
Use heater in accordance with all local codes. In the
absence of local codes, refer to The National Fuel Code,
ANSI A223.1/NFPA 54.
This heater is shipped from the factory for use with propane
(LP) gas only. Do not convert to any other gas. Installation
must conform to local codes or, in their absence, with
the standard for the Storage and Handling of Liquefied
Petroleum Gases ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
Gas supply connections should be checked by using a 50/50
WARNING
Figure 1
1. Remove all packing items applied to heater for shipment.
Keep plastic cover caps attached to inlet connector and hose /
regulator assembly for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If the heater is
damaged, promptly inform dealer where you purchased
the heater.
© 2018 Pinnacle Climate Technologies Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE
SAFETY INFORMATION (CONT.)
RISK OF ELECTRIC
SHOCK!
Electrical Grounding
Instructions: This
appliance is equipped
For use with propane
(LP) gas only.
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE. ALWAYS
LOCATE HEATER ON A STABLE AND LEVEL SURFACE (SEE FIGURE 1)!

UNPACKING

CONNECTED TO A POWER SOURCE
soap and water solution. Never use a flame to check for
gas leaks.
Locate LP cylinder at least 6 ft. (183 cm) (10 ft./305 cm
in Canada) from the heater, and do not direct heater
discharge towards the LP cylinder unless it is at least 20
feet (610 cm) from the heater.
Use only the regulator and hose assembly provided with
this heater. Inspect the regulator/hose assembly prior
to each use of the heater. If there is excessive abrasion
or wear, or if the hose is cut, replace it with the proper
assembly.
Manifold, Minimum, and Maximum Inlet Pressure
Man.
Min.
Max.
WARNING
material, and contact with hot surfaces during use
and while in storage.
X X
X
X
X
X
X
X
X
X X
X X X X
X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X
X
X
X
CAUTION
4
Propane Forced Air Heater User's Manual (ST-60HB2-GFA)
ST-60HB2-GFA
5 PSI
25 PSI
250 PSI
The hose assembly
shall be pro tected
from traffic, building
The Propane (LP) gas
pressure regulator
and hose assembly
supplied with the
heater must be used
without alteration.