EN
After the receiver and PIR sensor have been
DE
powered, press the
FR
Pairing button
ES
receiver. Next trigger the PIR sensor. If pairing is
successful, the receiver will play a ringing/alarm
IT
sound. It normally takes about 30 seconds for the
PIR sensor and receiver to pair. If there is no
pairing within 30 seconds, the receiver will
automatically exit pairing mode. Please try pairing
again.
E: Resetting and re-pairing:
If the receiver rings but the PIR sensor has not
been triggered, or the PIR sensor interferes with
another receiver, it may be necessary to wipe the
current pairings and pair again.
For Resetting the PIR sensors, press the Pairing
button and hold for 5 seconds. The receiver will
ring and flash a LED, then all the PIR sensors
information will be deleted.
You can now re-pair the wanted PIR sensor.
on the side of the
- 07 -
F: Installation:
The PIR sensor and receiver can be mounted on a
wall or just put on a flat place.
To mount on a wall:
Select a suitable location for the receiver and PIR
sensor.
Drill holes on the wall. Next push the wall plugs
into the drilled holes and then insert the screws
into the wall plugs. Finally, mount the PIR
sensor/receivers on the screws.
Note:
• The recommended installation height for the PIR
sensor is 3.3-4.9ft (1.0-1.5m)
• The PIR sensor detecting angle is 45 degree and
detecting distance is 16.4-26.2ft (5-8m). Install
the PIR sensor in key monitoring areas such as
the entrance to a garage, store, or house.
• If installing the PIR sensor outside, note that
moving leaves and branches, strong wind, and
drastic changes in temperature can affect and
influence the sensor.
• The PIR sensor and receiver can connect up to
300ft/100m without any obstacles.
• The PIR sensor's transmitting frequency is
- 08 -