Models BI29, BI41 and BI92, called "Dual", have a B thermostat and can be used both as
refrigerators and as freezers within the following temperature range:
BI29 Dual from +10°C to -12°C
BI41 Dual from +10°C to -10°C
BI92 Dual from +10°C to -20°C

2.2 Usage recommendations

If possible, the product should be turned on for about 6 hours prior to inserting
the food items.
• •
Frequent opening of the product will result in greater power consumption.
Frequent opening of the product will result in greater power consumption.
Ensuring adequate ventilation for the compressor and the condensing unit will
significantly reduce power consumption.
Never obstruct the product's ventilation system.
The electrical system must be kept in good condition. Inspect the batteries and
check the charge levels regularly. Always use a starter battery separate from the
motor.
Keep the inside of the product clean and dry. Remove the condensation water
from the drip tray beneath the refrigerator's freezer compartment where
present.
The product has been designed with a lock protection for the product itself in
the event of low battery voltage. In the event of a compressor block, follow
the instructions in this manual and/or contact specialised technicians or Indel
Webasto Marine Srl service centres.
The compressor can operate up to an angle of 30°, while greater angles can
cause permanent damage to the compressor.