Technical Data - Redsun E200 Manuel D'utilisation Et D'installation

Régulateur de temperature d'ambiance programmable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Technical data

Order Type
Supply voltage
Battery life
Temperature setting range
Temperature resolution
Switching current
Output
Output signal
Timing resolution
Accuracy of clock
Ambient temperature
Rated impulse voltage
Ball pressure test
Voltage and Current for the for
purposes of interferncemeasurements
Pollution degree
Degree of protection
Software class
Weight (with batteries)
54
E200
2 x AA 1,5 V alkaline batteries
3 years (typically)
7 °C to 32 °C
0,1 °C (setting and display)
max. 8(2)A; AC 24 ... 230 V~
Relay change over contact, voltage free
PID with PWM (pulse width modulation) or
ON/OFF selectable
1 minute
< 4 Min / year
Operating
0 °C to 40 °C not condensing
Storage
–20 °C to 85 °C not condensing
4 kV
75 °C
230 V, 0,1A
II (see Caution, page 46)
IP 30
A
~ 300 g

Publicité

Table des Matières
loading

Table des Matières