Fagor SBG9-10 Instructions Pour L'installation, L'utilisation Et L'entretien page 34

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Never start the appliance empty, as overheating could seriously damage the tub.
1
.-SBG9-10, SBG9-10I, SBG9-10S, SBG9-10IS
1
.- Water inlet tap.
2.- On lamp.
3.- Pilot light position lamp.
4.- Thermostat control.
5.- Gas tap control.
6.- Observation peep-hole on.
7.- Tub raising handle.
8.- Manual ignition hole.
SBG9-15 IM, SBG9-15I MS
1.- Water inlet tap.
2.- On lamp.
3.- Pilot light position lamp.
4.- Thermostat control.
5.- Gas tap control.
6.- Observation peep-hole on.
7.- Raise-lower switch.
8.- Manual ignition hole.
Open the main general gas-tap installed on the outside of the appliance.
1st Step Pilot Light Ignition
Turn the thermostat Mt control (Fig. 5) clockwise until the pilot light position (Fig. 7 - P1), at this moment the
"L1" lamp will light up (Fig. 5) indicating that it is ready for the "P" pilot light to be ignited (Fig. 5).
Next, press the solenoid valve Mv control (Fig. 5), whilst turning anti-clockwise to the pilot light position (Fig.
6 - P1). In this position, keep pressing the control until the "P" pilot light flame (Fig. 5) is permanently lit
(approximately 20 seconds).
2nd Step Ignition of burners
Pressing the solenoid valve control Mv (Fig. 5), rotate to burners ignition position (Fig. 6 - P2), it is ready
for the burners to be ignited.
To ignite the burners, press and turn the "Mt" thermostat control (Fig. 5) clockwise until the required
position, (Fig. 7, and). At this moment the "L2" lamp will light, indicating that the burners are functioning.
The required oil temperature (approximate) can be achieved turning the "Mt" control to selected position
(see table 3 for temperatures, indicating the temperature corresponding to each position on the control).
When the oil in the tub reaches the selected temperature, the burners will turn off by means of the
thermostat (lamp "L2" turns off). Also, as soon as the temperature drops below the selected value, the
burners will light up (switching on the L2 lamp).
Turing the burners off
Move from the position selected on the "Mt" control to the pilot light position (Fig. 9 - P1), so that only the
"P" pilot light is on (Fig. 7).
Turning the pilot light off
Move the "Mv" control to the "0" position (Fig. 8 - P0) and also move the "Mt" thermostat control to the "0"
position (Fig. 9 - P0).
2.-USAGE
2.-
SBG9-10M, SBG9-10IM, SBG9-10MS, SBG9-10I
MS
1.- Water inlet tap.
2.- On lamp.
3.- Pilot light position lamp.
4.- Thermos-tat control.
5.- Gas tap control.
6.- Observation peep-hole on.
7.- Raise-lower switch.
8.- Manual ignition hole.
4.-
SBG7-10
1.- Tub raising handle .
2.- Manual ignition hole.
3.- Observation peep-hole on.
4.- Gas tap control.
5.- Thermos-tat control.
6.- On lamp.
7.- Pilot light position lamp.
8.- Water inlet tap.
Burner ignition
33
Eliminado: ¶
Eliminado: ¶

Publicité

Chapitres

Table des Matières
loading

Table des Matières