Usage By Differently Able People - LEGRAND 5739 94 Notice D'installation

Masquer les pouces Voir aussi pour 5739 94:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3 - Remote control description

3.5 - Usage by differently able people

The radio remote control is equipped with:
– standard 3.5 mm single jack input for connection with a vacuum/blow sensor
– screw connection for anchoring on a wheelchair or a bed frame.
jack input
REMOTE CONTROL CONFIGURATION (DIFFERENTLY ABLE PEOPLE MODE)
Move the third switch to ON to enter the configuration mode.
Press the OK and C keys at the same time for two seconds to start an automatic scan on the first
six keys (video door entry system and available applications keys) which will continue for the
previously–saved scanning time, until the "+" key – which during the scan is on – is pressed.
When the "+"key is pressed, the scanning time between one key and another will be modified
and, consequently, the ongoing scan will continue for the newly–set scanning time.
Keep the "+" key pressed to cyclically change the time value among the pre–set ones, i.e. 0.3s,
0.5s, 1s, 2s.
Once you have selected the preferred scanning time value, press the OK key to move to the second
part of the configuration, i.e. the selection of the "beep" tone sounded by the beeper.
The shift from the scanning time setting mode to the sound level setting mode will be confirmed
by the "+" key LED turning off and the "–" key LED turning on.
Press the "–" key to select between the two pre–set tones.
The difference between the sound levels lies in the fact that by selecting one of the two the
frequency of the "beep" to be sounded will be changed. It is possible to choose between a 4KHz
and a 6.5 KHz frequency.
After selecting the sound level, press OK to terminate the configuration stage.
To exit the configuration mode, move the third dip–switch to OFF.
Please note that when you enter the configuration mode the scanning time values and the related
"beep" will be the ones previously set by following the same procedure or, if you are performing
the configuration for the first time, the default ones.
28
screw connection
From an electrical viewpoint,
the external sensors used
must be a closing contact.