Energy Efficiency; Energy Saving - Electrolux PBL64 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Rapid
Semi-rapid
Auxiliary
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
Rapid
Semi-rapid
Auxiliary

10. ENERGY EFFICIENCY

10.1 Product information according to EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Energy efficiency for the gas hob
(EE gas hob)
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General

10.2 Energy saving

• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
NORMAL POWER
kW
3,0
2,0
1,0
NORMAL
MINIMUM
POWER
POWER
kW
kW
2,8
0,75
2,0
0,45
1,0
0,33
MINIMUM POWER
kW
0,75
0,45
0,33
INJECTOR
MARK 1/100
mm
86
71
50
Left rear - Semi-rapid
Right rear - Semi-rapid
Left front - Rapid
Right front - Auxiliary
ENGLISH
INJECTOR MARK
1/100 mm
119
96
70
NOMINAL GAS FLOW g/h
G30 28-30
G31 37 mbar
mbar
204
200
145
143
73
71
PBL64V;
PNL64V;
PTL64V;
PXL64DV;
PXL64V
Built-in hob
4
59.2%
59.2%
57.4%
not applicable
58.6%
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pnl64Ptl64Pxl64

Table des Matières