Testing with the existing wires
1.
Make sure the existing kill switch wires are not in contact
after you have cut and stripped the two wires.
2.
Make sure your throttle or gear handle is in neutral position.
You are going to start the engine to check which principle is
used by your engine manufacturer.
3.
Turn the engine ignition switch to ON as you would normally
do when starting the engine.
If you have a pull cord, be sure to check if you can stop
the engine by pressing a STOP BUTTON on your
engine. If you do not have a STOP BUTTON on your
engine:
4.
Be sure to perform normal starting procedure when testing,
as described above in point 3.
5.
Yielded result:
No engine start:
Switch – Use blue wire and grey wire on the xHUB to
connect to the two existing kill switch wires in your
boat. See wiring diagram for Open to stop on page 28.
Engine start:
Switch – Use orange wire and grey wire on the xHUB
Cable to connect to the two existing kill switch wires
in your boat. See wiring diagram for Close to stop on
page 28.
25
In the event that the engine starts when the
existing kill switch wires are not in conductive
contact, and you have pulled the pull cord to
perform normal engine start, you can stop the
engine by reconnecting the wires. Simply by
leading them together on the stripped end of
both wires, where the cable metal is conductive.
WARNING – PREVENT ELECTRIC SHOCK: Be sure
not to touch the conducting surface on the wires
as these may conduct electricity!
You have a Open to stop (OS) Kill
You have a Close to stop (OS) Kill