When To Replace The Exhaust Filter; How To Replace The Airclean Exhaust Filter; Replacing The Airclean Plus 50, Active Airclean 50, And Hepa Airclean 50 Ex; Haust Filters - Miele Compact C1 Mode D'emploi

Masquer les pouces Voir aussi pour Compact C1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 Fit the filter bag into the holder as far
as it will go.
 Close the dust compartment lid se-
curely, making sure it clicks into posi-
tion. Take care not to trap the filter
bag when doing so.

When to replace the exhaust filter

Depending on the model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters (Fig.
09).
a AirClean
Replace this filter every time you start a
new packet of filter bags. Every packet
of original Miele filter bags contains one
AirClean exhaust filter. Multipacks con-
tain four AirClean filters.
b AirClean Plus 50 (light blue)
Replace this filter after approx. one
year. Make a note of the date on the ex-
haust filter.
c Active AirClean 50 (black)
d HEPA AirClean 50 (white)
Replace this filter when the TimeStrip®
exhaust filter change indicator is com-
pletely red (Fig. 14). The indicator lights
up after approximately 50 operating
hours, which is equivalent to about a
year of average use. You can continue
vacuuming when the light comes on.
However, the suction power will be re-
duced as will the effectiveness of the fil-
ter.
How to replace the AirClean exhaust
filter (Fig. 30 + 31)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Open the filter grille.
 Grasp the used AirClean exhaust filter
by the clean, unsoiled section and
take it out.
 Replace it with a new AirClean ex-
haust filter.
If you wish to fit an AirClean Plus 50,
Active AirClean 50, or HEPA AirClean
50 exhaust filter, see "Replacing one
type of exhaust filter with another".
 Close the filter grille.
 Close the dust compartment lid.
Replacing the AirClean Plus 50,
Active AirClean 50, and
HEPA AirClean 50 exhaust filters
(Fig. 32 + 33)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Lift the exhaust filter and remove it.
 Insert a new exhaust filter, making
sure it goes in properly, then push it
down into position.
 If you are using exhaust filter c or d,
press the TimeStrip® exhaust filter
change indicator (Fig. 12).
After approx. 10–15 seconds, a thin red
line will appear in the left hand side of
the display for both exhaust filters (Fig.
13).
If you wish to fit the AirClean exhaust
filter, see "Replacing one type of ex-
haust filter with another".
 Close the dust compartment lid.
en-US
19

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Scae03418

Table des Matières