Technical Data; Mechanical Data; Electrical Data - VALPES VT Manuel D'installation Et D'utilisation

Actionneur électrique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

Location
Materials
Sealing
Environment
Operating temperature
Operating altitude
Hygrometry
Pollution degree
Weight

Mechanical data

Nominal torque
Maximum torque
Operating time (90°)
Angular range
Duty cycle
Drive ISO5211
Manual control

Electrical data

Voltages
1)
Rated current
Overvoltage category
2)
Power
Torque limiter
Number of feedback switches
Limit switches maximum voltage
Limit switches maximum current
Anticondensation heaters
1)
The actuator tolerates voltage fluctuation of the electrical grid up to ± 10 % of its nominal system operating voltage
2)
The actuator tolerates temporary overvoltage of the electrical grid
20
VT1500
Housing: Aluminium + EPOXY paint / cover: PA6 UL 94 V-0 or Aluminium + EPOXY paint
Drive : Steel + Zn treatment / Axles and screws : Stainless steel
Both inside and outside (wet environments possible)
maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% rela-
Applicable POLLUTION DEGREE of the intended environment is 2
1200Nm
1500Nm
113s
F12/F14/F16 (depth F12 : 20mm / F14 : 25mm / F16 : 30mm)
Secured hand wheel without clutching system
230 V AC (50/60 Hz) • 3-phase 400 V (50 Hz)
400 V: 0,45 A (cos  = 0,8) • 230 V: 1,3 A (cos  = 0,8)
4 to 250V AC/DC (Overvoltage category II)
UK
VT2400
IP68
-20°C to +70°C
Up to 2000m
tive humidity at 40°C
(in most cases).
54kg
90° (180°-270° on request)
50%
Star 36 (depth 41mm)
250W
Mechanical
2 (4 on request)
1mA to 5A max
10W
DSBA3004 • Rév. 10/09/2019
ENGLISH
2000Nm
2400Nm
113s

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vt1500Vt2400

Table des Matières