8 ENCLOSURES
Min. safety distance from flammable materials
rear - right/left side - floor
CO emissions at 13% O2 in fumes
Dust emissions at 13% O2 in fumes
Max. water operating pressure
Flue gas temperature
Nominal and reduced heat output
Efficiency
Types of fuel
Electrical power
Rated voltage
Rated frequency
CE MARKING INFORMATION
FERROLI
2012
EN 14785 : 2006
Wood pellet-burning domestic heating appliances
MERCURIO
Ref.
:
Nom. output 151 ° C
:
Red. output 80.2 ° C
Nom. output 6.97 kW
:
Red. output 2.58 kW
Nom. output 91.6 %
:
Red. output 95.66 %
:
Wood pellets
420 W max - 120 w
:
:
230 V
:
50 Hz
60
200 – 300 – 0 mm
Nom. Output : 0.02 %
Red. output : 0.02 %
Nom. output : 13.7 mg/m
- bar
3
MERCURIO