Dometic WH-6GA Manuel D'installation Et D'utilisation page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

L.P. Gas Water Heater
Consider the following before wiring the control switch:
• The three-prong plug must be secured to a UL
approved, dedicated, minimum 15 A-rated, three-
prong receptacle.
• All wiring must comply with applicable electrical
codes.
• Use electrical metallic tubing, flexible metal conduit,
metal clad cable, or nonmetallic-sheathed cable with
a grounding conductor.
• Wires must have a capacity of 1400 W or greater.
• The wiring method must conform to applicable
sections of article 551 of National Electrical Code
ANSI/NFPA 70.
• The receptacle must be located per all applicable
codes and away from any water.
4.6.1 Configuring a Single Control Switch
r r
e e
10 Control Switch Wiring
Lock-Out Lamp
q
(Blue)
+12 VDC (Black)
w
1. Install the blue wire for the lock-out lamp from the
Water Heater onto the spade connector on the back
of the control switch.
2. Install the black +12 VDC wire onto the spade
connector on the back of the control switch.
EN
q q
w w
Control
e
(White/Orange)
Ground (Green)
r
3. Install the white wire or orange wire (depending on
the power source) from the Water Heater onto the
spade connector on the back of the control switch.
4. Install the green ground wire from the spade
connector on the back of the control switch to an
appropriate ground location.
4.6.2 Configuring a Single Combination
Control Switch
w
i i
u u
y y
i i
11 Single Combination Switch Wiring
Heating Element
q
Electronic Control
w
Lock-Out Lamp (Blue)
e
+12 VDC (Black)
r
I
Single combination control models require the use
of two switches. Assign and label one switch for the
gas heating element and one switch for electronic
control.
1. Install the blue wire for the lock-out lamp from the
Water Heater to the proper spade connector on the
back of the control switch assigned for the heating
element.
2. Install the black +12 VDC wire to the spade
connector on the back of the control switch assigned
for the gas heating element.
3. Install the orange wire from the Water Heater onto
the spade connector on the back of the control
switch assigned for the gas heating element.
Installation
q
e e
r r t t
Gas (Orange)
t
Electronic (White)
y
Ground (Green)
u
Jumper Wire
i
11

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Wh- 6geaWh-9geaWh-10geaWh-16gea

Table des Matières