Installation; Installation Layout; Hydraulic Connection; Electrical Connection - poolstar POOLEX PICO 3 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
3.2

Installation layout

POOL
The filter located upstream of the heat pump must be regularly cleared so that the water in the
system is clean, thus avoiding the operational problems associated with dirt or clogging in the
filter.
3.3

Hydraulic connection

Step 1
Screw the connectors to the heat pump
3.4

Electrical connection

The heat pump electrical plug integrates
a 10mA differential circuit breaker.
Before connecting your heat pump,
please ensure that the plug is connected
to the ground.
The filter pump should function at the
same time as the heat pump. Therefore,
you need to connect them to the same
electrical circuit.

3. Installation

TOWARDS THE POOL
Filtration + Pump
Step 2
Connect the water outlet pipe and the water
intake pipe
Automated treatment
system
FROM THE POOL
Power
indicator
Test
Reset
RESET