Materials
(1) Viton
(2) stainless steel (303 S21)
(2) fixing screws
(2) press-in catridge
(1) profiled seal / flat seal
(2) manual override
Compressed air
Adhere to the safety regulations and provisions for the installation of
pneumatic systems. Switch off pressure.
Connect the compressed air supply 1 (P), the pneumatic outputs (O-3,
O-4) and, if necessary, the exhaust 3 (R) to the pneumatic system. Cut
the connection tube straight and push it into the tube fitting until you
can feel the tube latch.
Removal of the tubes
To remove the tubes, push the black ring and pull out the tube at the
same time.
The manual overrides can operate the pneumatic outputs. Connect the
compressed air supply to the AS-i AirBox. If you then push the manual
override 1, the output O-3 is triggered. If you push the manual override 2,
the output O-4 is triggered.
(1) O-ring
(1) O-ring