NOTE: Make sure the vacuum is completely dry before using it again.
IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustments (other
than those listed in this manual) should be performed by an authorized service centers or other qualified
service organizations, always using identical replacement parts.
MAINTENANCE
Use only mild soap and damp cloth to clean the vac. Never let any liquid get inside the vacuum motor area;
never immerse any part of the vacuum into liquids.
IMPORTANT!
Clean or change the dust filter regularly for best performance. If the machine is used with
out the dust filter, the motor will burn out and the warranty will be voided.
IMPORTANT! Optimum dust collection will only be achieved with clean filters and an empty container. If
dust begins to fall out of the appliance after switching it off, this indicates that the dust bowl is full and must
be emptied.
WARNING: Never use the appliance without the filters installed.
WARNING:
TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE TROUBLESHOOTING
Symptom
Vacuum will not operate
Dust comes from motor cover.
Reduced efficiency and
motor/speed vibration.
TROUBLESHOOTING
Possible Causes
1) No power supply.
2) Faulty power cord.
3) Container full.
1) The reusable cloth filter is missing or
damaged.
1) There is a blockage in the nozzle, or
the vacuum inlets, or the dust filter is
blocked by fine dust.
Corrective Action
1) Check power supply – vehicle
battery , 12V power socket , cord,
breakers, and fuses.
2) Unplug and check the power
cord. If damaged, have it repaired
by a professional.
3) Empty container.
1) Attach or replace the reusable
cloth filter.
1) Check nozzle, and inlets for
blockage. Take off the filter and
clean it, or install new filter.