Télécharger Imprimer la page

Facom NK.3000F Notice Originale page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.581.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 3/4 to 1cm
through the machine's inlet connection.
3
Model
Square
Impact
drive
rate
''
NK.3000F
3/4
950
Model
Free speed
rpm
NK.3000F
5100
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT NK.3000F – FACOM 3/4" AIR IMPACT WRENCH
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-6:2012,
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-2:2009
NU-NK.3000F_1114.indd 7
• BEFORE EACH OPERATION, CHECK:
- Only use suitable FACOM sockets and flogging spanner accessories, (''IMPACT'') as well as
safety devices, bush and pin for mounting one of these cases on a drilled driving
square.
- The drive square condition (no marks, cracks or excessive wear).
- The condition of the safety devices (bush and pin) on the drilled square as well as the draw
bead on the non-drilled square.
Maximum
Torque
Pressure dB(A)
N.m
k*
2115
97,8
3
Air consumption
Working pressure
l/min
bar
178
6,2
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
Noise level
Power dB(A)
Pressure dB(C)
k*
k*
108,8
3
< 130
3
Weight
Dimensions
kg
mm
3,8
227x97x227
Vibrations
level
m/s
2
k**
5,06
0,99
06.09.2013
F
ACOM QUALITY MANAGER
11/27/2014 10:41:37 AM

Publicité

loading