1-09552_2972_2974_GA_EW_Primus_Quantum_Layout 1 13.08.2014 12:20 Seite 17
5.7 How the CO
Flipper works
2
The Flipper is a modern, highly effective CO
the most efficient possible use of the valuable CO
While CO
bubbles rise slowly in the Flipper, the CO
2
aquarium water. At the same time, other gases which are naturally
dissolved in the aquarium water penetrate into the CO
"waste gases" explain why the bubbles do not dissolve completely, despite
becoming smaller as they rise in the aquarium water. ©
The waste gases are substantially lighter than the relatively heavy
CO
and thus accumulate in the CO
2
discharged regularly via the special waste gas vent.
The running-in period for the Flipper is approx. 2 days.
Initially, the individual CO
bubbles combine to form larger bubbles.
2
As soon as a biological surface layer of microorganisms has formed,
the bubbles rise up to the collector.
5.8 Adapter for reusable CO
With the Dennerle adapter (art. no. 2999), Primus and Quantum
pressure reducers can also be connected to all standard reusable CO
cylinders (connection thread W21.8 x 1/14").
6 What if ... – Troubleshooting
Fault
Cause
A faint hissing sound
Pressure reducer is
is to be heard at the
skew or has not been
screwed connection
screwed in tight
between pressure
enough.
reducer and CO
Washer dirty or faulty.
2
cylinder.
No more bubbles at
Solenoid valve closed
the CO
diffusor.
CO
cylinder empty
2
2
Setting knob closed
Hose connection
leaking
Needle valve blocked
CO
bubbles stuck in
Flipper is still in the
2
the Flipper.
running-in phase.
Obstacles on the
channels (snails,
algae).
18
diffusor which ensures
2
fertilizer.
2
dissolves in the
2
bubbles. These
2
33
collector at the top. Here they are
2
cylinders
2
Remedy
Unscrew pressure re-
ducer and screw back
in place without can-
ting.
Clean sealing surfaces.
If necessary, replace
washer (Dennerle
Customer Service)
Open solenoid valve
Replace the CO
2
cylinder
Open setting knob
Check hose connection,
replace if necessary
Clean and recalibrate
the needle valve.
Await end of
running-in phase.
Clean.
Fault
Cause
Gas escaping from
Flipper not installed in
the side of the
vertical position.
collector.
Waste air vent (slit)
soiled.
7 Upgrades for CO
Level 1: CO
night cut-off valve: The Dennerle CO
2
off valve serves to cut off the CO
means of a time switch, as plants do not consume any CO
at night. This saves valuable CO
Level 2: Fully automatic: The Dennerle pH Controller Evolu-
tion measures the pH value in the aquarium continuously
and controls the supply of CO
tically via the CO

8 Technical data

8.1 Evolution Primus and Quantum pressure reducers
Maximum permissible cylinder pressure (operating pressure): 160 bar
2
Connection for hose 4/6 mm
Dynamic Valve Control (DVC) for precision control
Factory-calibrated precision needle valve with stainless steel needle,
adjustable via ultra-fine thread
Self-closing pressure-relief safety valve
8.2 Solenoid valve (Special Edition only)
230 V ~, 50/60 Hz
Power consumption: 1.6 W
Maximum permissible pressure: 5 bar
IPX 4 – splash-proof
9 Spare parts and useful accessories
(available from specialist retailers)
3013
Disposable CO
3047
Reusable CO
2
2999
Adapter for reusable CO
1484
Leak detector spray
3060
Special Softflex CO
3053
Special CO
check valve
2
3040
CO
long-term test Correct
2
2970
Profi-Line CO
2
3093
pH controller Evolution Deluxe
Remedy
Fit Flipper in an
upright position.
Clean.
fertilizer systems
2
night cut-
2
supply at night by
2
.
2
precisely and fully automa-
2
solenoid valve.
2
cylinder 500 g
2
cylinder, 500 g
cylinders
2
hose, 2 m
2
solenoid valve
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Einweg 300 quantum special edition

Table des Matières