Horizontal Termination with Three 90° Elbows (all vertical)
L'embout doit obligatoirement se trouver dans la zone hachurée du tableau. Utiliser les positions
indiquées pour les restricteurs et le diffuseur.
21' max (6.4m)
15 feet (4.5m)
10' min (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Fonctionnement
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
This is a horizontal elbow -
NOT ALLOWED FOR THIS
VENT CONFIGURATION
4100326
Restrictor
Position # 5
NOTE:
Restrictor positions are based
upon lab tests. The ideal restrictor
position may vary slightly,
especially when the termination is
near a demarkation line.
21' max (6.4m)
15 feet (4.5m)
10' min (3m)
5 feet (1.5m)
0 feet
These are
vertical elbows.
100-01250_000