Horizontal Termination with One 90° Elbow
L'embout doit obligatoirement se trouver dans la zone hachurée du tableau. Utiliser les positions
indiquées pour les restricteurs et le diffuseur.
19' max (5.8m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
© Travis Industries
Fonctionnement
Restrictor Position # 5
Restrictor
Position # 1
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
NATURAL GAS: Min. 2' (0.61m) Section Required
PROPANE (LP): Min. 3' (0.915m) Section Required
4100326
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
19' max (5.8m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01250_000