NORMAL ANNUAL SERVICING
Like all mechanical devices, it is necessary to clean the TOBY oil controls at certain intervals, as a rule every 1-2
years. If particularly dirty fuel oil is used, additional cleaning may prove necessary.
The following sequence should be carried out during the annual overhaul:
1. Tap the actuating pin, with the control knob set at the highest position. In this way, any slight accumulation
of dirt in the metering stem slit will be removed.
2.
Remove the oil coke from the burner feed valve so that the fuel can flow unobstructed to the burner.
3.
Remove and clean the filter and refit it.
Removal of the locking nut
Removal of the filter screw.
Cleaning the filter in fresh fuel
oil, benzine, petrol, kerosene or
hot water.