The complete installation must be carried out with due reference to the Standards and local Codes. It should be
noted that the requirements and these publications may be superseded during the life of this manual.
We recommend the installation of the stove is carried out by suitably qualified persons working to the local Codes
and rules which are current at the time of installation.
Measurement
(mm)
H11 / S21
S31
S41 / H41
The measurements given are for advice only. In all installations surrounding flammable materials must not exceed
80°C. The stove must always stand perfectly level and have sufficient space allowed for service work. These
clearances can be reduced by:
A. Using heat shield as listed in AS/NZS2918:2001 or AS1691:1985
B. Using a sheet metal spacing 22 mm from the wall, clearances may be reduced by 50%.
SEISMIC RESTRAINTS
The stove must be fixed to the floor using two heavy wood screws (for a
wooden floor) or 2.5 mm Dynabolts or similar device, for a concrete floor.
The restraints should be fitted through the holes in two diagonally
opposite feet.
1. INSTALLATION
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
A
B
450
300
450
300
450
400
Our oil stoves do not require the use of floor protection.
F
Corner installations
C
D
200
250
200
300
200
300
C07100DC023
45
G
E
F
300
300
300
300
400
400
G
300
300
400
46