Troubleshooting
If a problem occurs, always observe the charge-status and fault indicator of the battery. See the section
headed Status indicators of the Li­ion battery.
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
Product does not develop full
power.
The battery does not engage
with an audible click.
Product does not start.
The saw blade cannot be
removed from the chuck.
10
Disposal
WARNING
Risk of injury due to incorrect disposal! Health hazards due to escaping gases or liquids.
▶ DO NOT send batteries through the mail!
▶ Cover the terminals with a non-conductive material (such as electrical tape) to prevent short circuiting.
▶ Dispose of your battery out of the reach of children.
▶ Dispose of the battery at your Hilti Store, or consult your local governmental garbage disposal or public
health and safety resources for disposal instructions.
Most of the materials from which Hilti products are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti sales representative for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
11
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
12
Further information
For more information on operation,
qr.hilti.com/manual/?id=2243125
This link is also to be found at the end of the documentation, in the form of a QR code.
12
English
Possible cause
The control switch is not fully
pressed.
Battery is discharged.
The retaining lugs on the battery
are dirty.
The battery is not correctly in-
serted.
Battery defective.
Damage to the product
The locking lever was not pushed
as far as it will go.
Blade holder clogged by residues
from sawing operations.
technology,
environment and recycling,
Action to be taken
▶ Press the control switch fully.
▶ Change the battery and charge
the empty battery.
▶ Clean the retaining lug and refit
the battery.
▶ Push the battery in until it
engages with a click.
▶ Contact Hilti Service.
▶ Have the product repaired by
Hilti Service.
▶ Push the locking lever as far as
it will go and remove the saw
blade.
▶ Remove the residues from
sawing operations and regularly
clean the blade holder from the
outside. Care of the product.