imperatively be respected before destruction of packaging.
Carefully remove all protective part.
If any doubt as far as the good operating of your appliance wait to use it the council of
qualified technician.
Put the appliance in position, being careful to level it perfectly by rotating the adjustable
feet.
To prevent damage due to steam coming out of the appliance during normal operation,
make sure that the materials nearby will not be deteriorate if exposed to steam.
Before connecting the appliance to the water supply and the electric mains, make sure
that the general characteristics and technical data indicated on the data plate (C3) are in
accordance with those of the site. Repairs must be performed only with original spare
parts furnished by the manufacturer.
Any other non-authorized intervention or using non proper spare part will invalidate
warranty
3. Plumbing and electric connections
Water supply
Before connecting the appliance, make sure that there is a gate valve between it and the
water main supply in order to be able to shut it off when necessary or in case of repair.
Minimum water supply pressure, measured at the machine water intake during final
rinsing (flow pressure) must not be less than 180kPa (1.8 bar) or more than 400kPa (4
bar), even when other taps are opened on the same line. To prevent pressure or load
drops, we recommend that each appliance should have its own supply pipe line, that
must be sufficiently short and of adequate size. If the pressure is lower than the
minimum required complementary pump has to be installed (available as option). If the
static pressure is higher than 6bar, then a pressure reducer must be installed upstream
from the supply pipeline.
Check the supply water temperature is equal to the values given in technical sheet. To
obtain good washing results, we recommend that the hardness of the supply water
should be within 7 and 12°F. If the hardness of the water is higher than 12°F we
recommend installing a water softener upstream from the fill-up solenoid valve, rated for
5-7°F residual hardness.
Use a flexible hose to connect the fill-up solenoid valve to the supply tap.
Respect all current National or Regional regulations in force.
Draining
The drain pipe must be connected to a sump or to a floor drain. Make sure that the drain
pipelines in the wash area are not choked and that they afford a quick water outflow.
The wall drain pipe must support a minimum temperature of 70°C. This appliance has a
gravity drain, so the outlet of dishwasher must be lower than the tank inlet. If the
appliance is equipped with a draining pump, the connection must be on the wall as
indicated on picture D.
Electrical connexions
26