13. AQUATIMER A3000 open – Variant 2
Connection example for electrical installation
Electric T-junction in the in-wall installation box
Materials required
To be provided by the customer:
• Earth leakage circuit breaker (RCD)
• Conduit for system line
Accessories
Function controller
with Ethernet connection
ECC2 . . . . . . . . . . . . . . . . . . . . . . . . . 2000108123
System line
blue, 100 m . . . . . . . . . . . . . . . . . . . . 2000104272
blue, 25 m . . . . . . . . . . . . . . . . . . . . . 2000104274
gray, not halogen-free, 100 m . . . . . . 2000100801
gray, not halogen-free, 25 m . . . . . . . 2000100852
Terminating resistor . . . . . . . . . . . . . . . 2000100847
Preparing the electrical connection
Position the power supply outside of the wet area, in a separate room, and protect it
with an earth leakage circuit breaker (RCD).
Important!
Only use original lines.
Lay the system line (a) through the conduit, and loop it from the damp-room junction
box to the damp-room junction box.
Let the system line hang out of the in-wall installation box approx. 50 cm.
13.1 Connect the electric T-junction (b).