Technical specifications
Model Wahlbach
Nom. power rating
Electric supply
Nominal current
Cable size
Flow rate (Δt=25K) L/m 2,0L/min.
Heating system
Min. water resi-
stance at 15°C
Switch on flow rate
Max. inlet temperature
Non-usage consumption <0,1Wh/h
Protection class
T ype of protection
Dimensions
heater (H x W x D)
Unit weight
Water connections
Distance water
connections
Max. pressure
water mains
Switch on flow
pressure
Daily electricity
consumption (Q
Load profile
Sound power
level (L
)
WA
Energy
efficiency (η
wh3
Mini 3.5 E
230V, 50Hz.
3,5kW
16A
3x 1,5mm²
unvented
≥ 1300Ωcm
1,2L/min.
30°C
I
IP24
135 x 186 x 87mm 135 x 186 x 87mm 135 x 186 x 87mm
1,5kg
G⅜"
30mm
0,8MPa
0,05MPa
) 1,263 kWh
elec
XXS
16 dB
40,0 %
)
DE GB NL FR
Mini 4.5 E
230V, 50Hz.
4,5kW
20A
3x 2,5mm² (not
included)
2,6L/min.
unvented
≥ 1300Ωcm
1,4L/min.
30°C
<0,1Wh/h
I
IP24
1,5kg
G⅜"
30mm
0,8MPa
0,05MPa
1,260 kWh
XXS
16 dB
40,0 %
Mini 5.5 E
230V, 50Hz.
5,5kW
24A
3x 2,5mm² (not
included)
3,1L/min.
unvented
≥ 1300Ωcm
1,6L/min.
30°C
<0,1Wh/h
I
IP24
1,5kg
G⅜"
30mm
0,8MPa
0,05MPa
1,268 kWh
XXS
16 dB
40,0 %