10.4 Switch positions (S14...S16) for linearisation
A switch combination has to be set to linearise the range that
depends on the minimum value of the measuring range (TA)
and the temperature range (TE – TA). Fig. 7 shows how the
switch positions are determined for the example of a
600
500
400
300
200
100
0
–150
–100
–50
Fig. 7. Switch positions (S14...S16) for linearisation.
TA = Measuring range start value
TE = Measuring range end value
10.5 Jumper plug positions for output signal range
There is a jumper plug for each channel that enables the
output current range to be selected (see Fig. 8).
Current
[mA]
0...20
4...20
26
0
50
100
150
Start temperature TA in °C
Plug-in jumper
measuring range of 100...600 °C. The correct switch positions
for this example are "OFF–ON–ON".
Example:
meas. range
100...600 °C
200
250
300
350
DIP switch
for channel 2
Soldered jumper
for channel 2
S1...S8
S9...S16
Span
Zero
2
1
S1...S8
S9...S16
Span
Zero
Soldered jumper
for channel 1
DIP switch
for channel 1
Fig. 8. Position of the DIP switches S1...S16, plug-in jumpers and
soldered jumpers.
ON
OFF
400
450
Plug-in jumper for
output signal to channel 2
Plug-in jumper for
output signal to channel 1