Télécharger Imprimer la page

HERKULES SHZ 250 Instructions D'origine page 16

Commande bowden à câble

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
SHZ 600-1
Voltage (V) .............................. 220-240 V ~ 50 Hz
Rated current (A) ............................................ 4,6
Power consumption (W) ............................... 1050
Operating mode ...........................ED 20% 10 min
Rated load (kg) ......................................300 / 600
Lifting height (m) ..........................................18 / 9
Rated speed (m/min) .....................................8 / 4
Diameter of steel cable (mm) .......................... 4,5
Tensile strength of the
steel cable (N/mm²) ..................................... 1870
Insulation class .................................................. B
Protection class ........................................... IP 54
Drive unit class ................................................. A1
Net weight (kg) .............................................. 16,8
Operating mode ED – 20% - 10 minutes: ED =
Intermittent mode without infl uencing the starting
process. This means that the maximum operating
period over a time of 10 minutes is 20% (2 minu-
tes).
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
The cable hoist is not suitable for transporting
hot and/or molten masses and in addition it is
not suitable for use at low temperatures or in
aggressive atmospheres.
It is in mechanical group A1.
The service life of the cable hoist is approxi-
mately 8000 cycles (excluding wearing parts).
When the hoist has completed 8000 cycles,
Anl_SHZ_250_600_SPK7.indb 16
Anl_SHZ_250_600_SPK7.indb 16
GB
all its mechanical parts must be checked and
overhauled.
Read and absorb the operating instructions
before you use the cable hoist.
Ensure that the operator knows how the ma-
chine works and how it should be operated.
The user should always operate as set out in
the operating instructions.
The cable hoist is not designed for conti-
nuous operation. Its mode of operation is:
Intermittent mode without influencing the star-
ting process.
The rated capacity of the machine does not
vary due to the position of the load.
5.1 Unpacking
After opening the packaging, inspect the frame,
the steel cable, the hook and the electric control
mechanism for signs of possible transit damage.
5.2 Assembly (Fig. 5)
The cable hoist is fi tted with two fastening bars
(1) with which it has to be fastened to a rectangu-
lar tube. The dimensions of the arm must conform
with the size of the fastening bars (1) and must
be capable of supporting twice the rated load. We
recommend that you seek advice from a qualifi ed
technician.
All screws must be tightened correctly. A qualifi ed
technician should check the anchoring of the arm
before the machine is started.
5.3 Block and tackle function (Fig. 6 – 9)
The cable hoist is fi tted with a return roller (15)
and an additional hook (16). If these parts are
used correctly, the cable hoist can lift twice its
rated load.
Fit the return roller (15) and additional hook (16)
as shown in Figure 6 – 8. The permanent hook (8)
must be attached to the fastening hole (2) (Fig. 9).
The load is now raised by two steel cables, which
means that the cable hoist can lift twice its rated
load.
6. Operation
Danger!
6.1 Information for operation
1. Remove the adhesive tape from the drum (3)
before using the hoist for the fi rst time.
2. The value of the A-rated noise emissions at
the operator's position is less than 75 dB.
3. Supply voltage: 230 V ± 10%, 50 Hz ± 1%.
- 16 -
18.08.2020 08:49:49
18.08.2020 08:49:49

Publicité

loading

Ce manuel est également adapté pour:

Shz 250-18Shz 500-18Shz 600-1