Information about this operating manual
Please read the operating instructions and familiarise yourself with the unit prior to using it for the first time.
Adhere to the safety information for the correct and safe use of the unit.
Intended use
The CFP 3500, 5500, 8500, 11500 series, in the following text termed unit, has been exclusively produced for
pumping normal pond water for filters, water falls and water courses and has to be used at a water temperature
of between 4°C and +35°C and an operating voltage of 230 Volt.
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the
case of misuse. If used for purposes other than that intended, our warranty and operating permit will become
null and void.
Safety information
Tetra has manufactured this unit to the current state of the art and the valid safety regulations. Despite of the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in
accordance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognise
possible danger or who are not familiar with these operating instructions, are not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when
passing the unit on to a new owner. Ensure that all work with this unit is only carried out in accordance with
these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected
or misused. Only operate the unit if no persons are in the water! Prior to reaching into the water, always
disconnect the power supply to all units used in the water. Compare the electrical values of the power supply
with those on the type plate on the packaging or on the unit itself. Ensure that the unit is fused for a rated
residual current of max. 30 mA via a residual current-operating system. Only operate the unit when plugged
into a correctly fitted socket. Keep the power plug and all connection points dry! Protect the connection cable
when burying to avoid damage. Only use cables, equipment, adapters, extension or connection cables with
an earthed contact and approved for outside use. Do not carry or pull the unit by the connection cable! Never
operate the unit if the cable or housing are defective! CFP 5500, 8500, 11500: In case the mains connection
cable of the unit is damaged, have it replaced by the manufacturer or the customer service in order to prevent
hazards. CFP 3500: This unit does not allow a change of the power cable! If the cable is damaged, the entire
unit has to be disposed of. Electrical installations at garden ponds must meet the international and national
regulations valid for installers. Never open the unit housing or its attendant components, unless this is explicitly
mentioned in the operating instructions. Never carry out technical changes to the unit. Only use original spare
parts and accessories. Never run the unit without water! Never use the pump for fluids other than water! For
your own safety, consult a qualified electrician if you have questions or encounter problems!
Electrical connection
Only entrust an authorised expert to carry out the electrical connection in accordance with local regulations.
VDE 0100 Part 702 is valid for all installations. Refer to the type plate for all capacity parameters. Only perform
any work on the unit when isolated!
Start-up
Attention! Never operate the unit without filter basket or without water!
Only use the unit in its horizontal position and ensure stable seating on a firm ground. The unit must be positioned
below the water surface level. Cut the stepped hose connectors to suit the hose diameter. Connect the hose.
We recommend to secure the hoses with commercially available hose clips (not included). The unit switches
on automatically when connected to power.
Maintenance and cleaning
Attention! Always disconnect the power supply prior to starting cleaning and maintenance work!
Important! CFP 5500, 8500, 11500: Never open the pump yourself! Contact a qualified electrician if the rotor is
blocked by soiling!
CFP 5500, 8500, 11500: Should the capacity drop, clean the filter housing under running water using a soft brush.
Pull the power plug prior to starting cleaning. Please undo the screws on the underside of the strainer casing
(B5) and open the lock on the front. Open the strainer casing and remove the pump from the filter casing (B6).
6
Clean the pump under running water using a soft brush. Remove soiling from the impeller vanes through the
openings. Never open the motor housing. Danger to life! After cleaning, fit the unit in the reverse order.
CFP 3500: Dismantle the pump (C) if the rotor is blocked by soiling: Screw off the pump housing. Pull out the rotor,
clean, check and, if necessary, replace. Reassemble in the reverse order.
Wearing parts
CFP 3500: The impeller unit including bearing and axle are wear parts and are excluded from the warranty.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for damage
and store immersed in water in a frost-free environment. Do not immerse the plug! (D)
Disposal
Dispose of the unit in accordance with the national legal regulations.
Problem Solving
Problem
Pump does not start
No mains voltage
Pump does not deliver
Filter housing clogged
Filter housing clogged
Insufficient water flow
Excessive frictional flow loss in the hoses
Pump switches off after
Excessively dirty water
Water temperature too high
a short running time
Pond keeping information
If you have any questions regarding your pond or water garden contact Tetra at: Tetra (UK) Ltd, P.O. Box 271,
Southampton, SO18 3ZX or visit our Web Site on http:\\www.tetra.net
3 year guarantee
Tetra guarantees that this TetraPond unit will be repaired or replaced free of charge within three years from the
purchase date, if it fails due to defective materials or poor workmanship.
This guarantee does not cover normal wear and tear, nor any deterioration suffered through overloading,
improper use, negligence or accident. Similarly any modifications made by the purchaser to the appliance will
cause the guarantee to be null and void. Please keep your receipt as proof of purchase and return the enclosed
guarantee card within 14 days in order to validate your guarantee.
Appliance in the pond:
max. pumping height
(m)
CFP 3500
,7 m
CFP 5500
,5 m
CFP 8500
3, m
CFP 11500
3,3 m
Cause
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary
minimum, do not use unnecessary
connection parts
Clean strainer casings
Reduce hose length to the necessary
minimum, do not use unnecessary
connection parts, use recommended hose
diameters
Clean pump
Note maximum water temperature of +35°C
water flow
combination with
(l/h)
TetraPond Filter
300
PFC-UV 8000
5500
PFC-UV 16000/ PFX-UV 5000
8100
PFC-UV 16000/ PFX-UV 8000
11500
PFX-UV 1000
UK
7