The following example and table shall explain the designations
of the machine safety sensors:
 Example:
 6 71 2 71 M U 0
 6 ab c de f g h ij kl
Characteristic
6
Model
ab
Housing type
c
Variant
de
Switch type
f
Ex-version
33/135
6
Ex-version Sensors
71
M30 stainless steel housing (material
no. 1.4571, 1.4305 or 1.4401)
Resistors and reed contacts resin
encapsulated
Cable output with wire ends
2
Machine safety sensor (MSS)
V
Machine safety sensor (MSS)
two isolated contacts (4 wire)
61
Three Normally Open contacts system
62
Two Normally Open contacts system
71
Normally Open / Normally Closed con-
tact system
M
resin-encapsulated (Ex m); without
earth terminal;
for connection to non-intrinsically safe
circuits
N
resin-encapsulated; with earth terminal;
for connection to non-intrinsically safe
circuits
I
intrinsically safe (Ex i); without earth
terminal;
for connection to intrinsically safe cir-
cuits
K
intrinsically safe; with earth terminal;
for connection to intrinsically safe cir-
cuits
Meaning