Télécharger Imprimer la page

Velleman DVM1000 Mode D'emploi page 3

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DVM1000 – 3 IN 1 MULTIMETER – CABLE / LINE TESTER
1. Introduction & Features
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the
device was damaged in transit, don't install or use it and contact your dealer. This 3 in 1 digital multitester has been
designed to combine the functions of a digital multimeter, a telephone line tester and a network cable tester. Contents:
1 x multimeter, 1 x set of test leads, 1 x 9V battery and this manual.
Features:
• DC voltage measurement, 5 ranges from 200mV to 1000mV
• AC voltage measurement, 5 ranges from 200mV to 700mV
• DC/AC current measurement, 5 ranges from 200 A to 10A
• Resistance measurement, 7 ranges from 200 to 200M
• Diode test
• Audible continuity test
• Battery test: 1.5V/6V/9V
• Telephone line test (RJ11)
• Network cable test (RJ45)
2. Safety Instructions
To ensure safe operation and in order to exploit the full functionality of the meter, please follow the
directions in this section carefully.
This multimeter has been designed according to IEC-1010 concerning electronic measuring instruments with an
overvoltage category CAT II 1000V, CAT III 600V and pollution 2.
• Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer
will not accept responsibility for any ensuing defects or problems.
• When using this meter, the user must observe all normal safety rules concerning protection against the danger of
electroshocks and protection against misuse.
• The test leads must always be in good condition. Before using, verify that the insulation on the test leads is not
damaged and/or the wires are not exposed.
• Full compliance with safety standards can only be guaranteed if used with the supplied test leads. They must be
replaced with the same model or the same class.
• Never exceed the protection limit values indicated for each measurement range.
• Do not touch unused terminals when the meter is linked to a circuit.
• When the value scale to be measured is unknown, set the range selector at the highest position.
• Disconnect the test leads form the circuit under test before rotating the range selector.
• When carrying out measurements on TV or switching power circuits, there may be high amplitude voltage pulses
which may damage the meter.
• Never perform resistance measurements on live circuits.
• Always be careful when handling voltages > 60VDC or > 30VAC RMS. Always keep fingers behind the guards.
DVM1000
- 3 -
VELLEMAN

Publicité

loading