Water Supply - Scotsman Prodigy Plus Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EH222 D and Condensing Unit
Remote Low Side Cuber User Manual

Water Supply:

A 3/8" flare nut on tubing is located at the top panel,
near the refrigeration tubing.
Inside the hardware bag, inside the cabinet, a
3/8" inch double male flare adapter (flare union) is
supplied. Use the supplied adapter to make a 3/8"
male flare fitting for the water inlet.
Connect a cold, potable water supply to the 3/8" water
inlet fitting installed above. Use 3/8" OD copper or
other comparable sized tubing for the water supply.
Note: This is an NSF listed ice machine and contains
provisions for back-flow prevention in its design. No
external back flow preventer is required.
Communication Cable
Suction Line Insulation
Water Supply Connection
October 2014
Page 14

Publicité

Chapitres

Table des Matières
loading

Table des Matières