The parameters listed below must now be entered correctly before the actual charge or
discharge process can be started.
The setup menu required for this appears on the screen automatically when you connect
the battery to be charged.
In the following section we assume that the screen is set to „LONG DISPLAY" mode. The
display mode can be toggled between LONG and SHORT using the double button function
(press the UP and DN buttons briefly together). See appendix for a screen short of the
„SHORT DISPLAY".
The parameters to be set are selected initially by leafing through the menu using the UP
and DN buttons; the value is set using the CURSOR buttons. The left and right buttons are
used to select the numbers to be changed, the top and bottom buttons to change the sel-
ected value.
-
Setting the charge current: select SET CH, set the charge current using the CURSOR
buttons.
-
Setting the discharge current: select SET DC, adjust the discharge current using the
CURSOR buttons.
-
Setting the termination temperature: select S.CH.C.TEMP., adjust the termination
temperature using the CURSOR buttons.
-
Setting the Delta Peak sensitivity: select S.CH.DELTA, adjust the Delta Peak sensi-
tivity using the cursor buttons. Values for NiCD packs are between 3mV/cell and
20mV/cell. For charging NiMH batteries the 0DV value must be set.
-
Setting the final charge voltage: select S.CH.CUT, this should normally be set to the
maximum value of 53 V.
-
Setting the final discharge voltage: select S.DC.CUT, set the desired final discharge
voltage using the CURSOR buttons. Recommendation: approx. 0.8 V per cell.
-
This concludes the parameter setting process.
-
By pressing the MODE button you can switch between CHARGING, DISCHARGING,
DISCHARGE-BEFORE-CHARGE (DISC-CHAR 01TIME) and CHARGE-BEFORE-
DISCHARGE (CHAR-DISC 01TIME). The number of cycles (xxTIME) in the DISCHAR-
GE-BEFORE-CHARGE and CHARGE-BEFORE-DISCHARGE processes can be set to
any number in the range 1 - 99 using the CURSOR buttons.
-
Press the START/STOP button to start the selected process.
-
The charge or discharge process is ended by the automatic termination circuit (Delta
Peak and/or temperature monitoring) or by the operator pressing the START/STOP but-
ton.
Menus / screen displays
The menu structure: the screen displays shown below can be selected using the UP / DN
buttons. The parameters described above are set using the CURSOR buttons.
robbe
OUTPUT 11.720 V
Operating instructions
POWER PEAK MAXAMP
Power-on display
C
Display momentary battery voltage
12
Order No.
8121