3 - settinGs

3.1 - User Parameters settinG - level 1
Press the set button once to enter the menu level 1 (see table):
name
H2O pressure
Pump Speed selection
Water flow
Sensors reading
Working mode selection
Error List
Language selection
• Utilise buttons s or t to select the desired parameter.
• Press set to visualise or modify the selected parameter.
• Press set to confirm any changes.
• Press the button
3.2 - aUtHorizeD serviCe Center Parameters settinG - level 2
• Press and hold set button for 3 seconds to enter the menu level 2 (see table on the next page).
• The parameter for the setting of the pump mode will be displayed.
• Press set to modify the pump mode (see P03) or press buttons s or t to enter the parameter list (the list
is accessible only by password).
• Enter the password and confirm with the set button.
• Press buttons s or t to scroll through the parameters.
• Press set to visualise the selected parameter.
• Press and hold set button for 3 seconds to modify the parameter. The parameter value will blink to indicate
the change in progress.
• Press buttons s or t to change the parameter value.
• Press set to confirm or
• Press the button
leGenD of aCronYms (ContaineD in tHe Parameter taBles)
DHW: DOMESTIC HOT WATER
RWT: RETURN WATER TEMPERATURE
SWT: SUPPLY WATER TEMPERATURE
OAT: OUTDOOR AIR TEMPERATURE
ICT1: OUTLET (HEAT) / INLET (COOL) HEAT EXCHANGER (PLATE-TYPE)
ICT2: INLET (HEAT) / OUTLET (COOL) HEAT EXCHANGER (PLATE-TYPE)
OCT: OUTDOOR COIL TEMPERATURE
CDT: COMPRESSOR DISCHARGE TEMPERATURE
CTST: COMPRESSOR TOP SHELL TEMPERATURE
ICP: CONDENSATION PRESSURE (HEAT) / EVAPORATION PRESSURE (COOL)
Description
Water pressure in the water circuit
Select the water pump speed and
read back the corresponding water
flow
Water flow level bar
List of main sensors reading
HEAT: heating mode selected
COOL: cooling mode selected
List of last 10 errors
0= French
1= English
2= Italian
to return to the previous menu.
to cancel.
to return to the previous menu.
notes
Once desired speed has been se-
lected, press button
the selection
RWT, SWT, OAT, Water Flow, Pump
Speed
Selection available only if P14 = 1
See parameter P04
Hold button s for 5 seconds to de-
lete the list (possible only if P07 = 1)
See parameter P08
5
5
EG
to confirm