4. Operation
Thermostat
The room temperature is
regulated using the infini-
tely adjustable thermo-
stat. If the rotary knob is
set to the lowest setting
i.e. to the extreme left
(see figure), the thermo-
stat switches the heating
device on at an ambient
temperature of approx.
5° - 8° C. During boost
(see below), the thermo-
stat does not work
Switches and buttons
The device has one On/Off switch and four buttons with tellta-
les. The buttons can be used to select the following functions:
Heating level I, heating level II
Various levels of heating output can be set, see table.
Button for
WW 101 E
Heating level I
400 W
Heating level II
600 W
Heating level
1000 W
I and II
Comfort
The temperature set on the thermostat's rotary knob is taken
into account.
Setback
The temperature set on the thermostat's rotary knob is reduced
by around 4° .
Boost
The temperature set on the thermostat's rotary knob is not ta-
ken into account. Heating levels I and II are activated.
Press "Boost" button once: light is red; boost for 30 minutes.
Press "Boost" button twice: light is green; boost for 1 hour.
Press "Boost" button again: boost deactivated.
Warning!
Depending on the size of the room, heat requirement and ther-
mostat setting, rooms may overheat if the heating is not con-
trolled. This can be dangerous for people who are not able to
leave the room as it gets too hot.
5. Protection Against Overheating
If the permissible temperature is exceeded, the heating device
switches off automatically. If this occurs, disconnect the mains
plug and leave the device unplugged for a few minutes, so that
the temperature limiter can switch back again.
Then rectify the cause e.g. when the air grid is blocked or co-
vered. When the device has cooled sufficiently, it can be star-
ted up again.
WW 151 E
WW 201 E
500 W
750 W
1000 W
1250 W
1500 W
2000 W
6. Faults
If the heating device is not emitting heat, check the following
points:
• Is the power switch in the ON position?
• Has the thermostat been set to the desired temperature?
• Has the overheat protection been triggered? See chapter 5!
• Is the fuse in the fuse box switched on?
If you cannot remedy the fault, please contact your electrical re-
tailer. If required, you can also contact the service hotline of
Glen Dimplex Deutschland GmbH.
Tel.: +49 (0) 9221 709-564
Fax: +49 (0) 9221 709-589
To process your order, please state the device type as well as
its production number (E Nr.) and manufacturing date (FD).
This information can be found on the type plate.
Repairs and corrective measures may only be carried out by a
qualified electrician or your after-sales service.
7. Cleaning
To clean the device, first disconnect it from the mains and allow
it to cool down. Clean the outside of the unit using a soft, damp
cloth. Do not use scouring powder or furniture polish as these
may damage the surface. Dust which gathers inside the device
can be removed from the outside using a vacuum cleaner.
8. Technical Data
Model
WW 101 E
Nominal power
1000 W
Dimensions
635 x 468 x
wall mounted
140 mm
(W x H x D)
Dimensions
635 x 500 x
free-standing
275 mm
(W x H x D)
Weight
4.7 kg
Connection voltage:
1/N 230-240V~
Degree of protection: IP24 (splash protection)
Protection class:
II (with protective insulation)
9. Warranty
This product is supplied with a two-year warranty according to
our terms of guarantee.
10. Note on Disposal
Do not dispose of the device with general household
waste. The device must be taken to a local waste dis-
posal plant.
Glen Dimplex Deutschland GmbH
Am Goldenen Feld 18
D-95326 Kulmbach
kundendienst.hauswaerme@dimplex.de
5
WW 151 E
WW 201 E
1500 W
2000 W
835 x 468 x
1035 x 468 x
140 mm
140 mm
835 x 545 x
1035 x 545 x
275 mm
275 mm
6.0 kg
7.4 kg
ww1e-en_ba 03/11/A
www.dimplex.de

Publicité

loading

Ce manuel est également adapté pour:

Ww 151 eWw 201 e