Télécharger Imprimer la page

Bticino U1637B Notice D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
Signalling LED
Mode SPE=0 (no configurator)
This mode allows you to execute all the standard functions of the control
Possible function
ON/OFF cyclical functioning for short pressure
and adjustment for long pressure
ON
timed ON
1)
OFF
ON pressing the key connected in N1 - OFF pressing the key
connected in N2 and adjustment for long pressure (dimmer)
Up (N1) - down (N2) rolling shutters to end of travel
Up (N1) - down (N2) monostable rolling shutters
Pushbutton
1)the device sends an OFF command after a time period determined by
the configurators used, as shown in the table below:
Configurator
Time (minutes)
1
1
2
2
3
3
4
4
5
5
6
15
7
30 seconds
8
0,5 seconds
Advanced modes of operation
If the SPE position is appropriately configured, as well as the M position,
the device will execute special functions listed in the table shown in the
following page.
The DIN F428 contact interface lets you connect two
generic switches or contacts to the SCS bus, thus letting
Input terminals
you achieve most advanced functions in a special con-
trol as well as all the standard functions of a normal SCS
control.
The N1 contact controls the PL1 light point, contact N2
controls the PL2 light point.
The device is equipped with 2 LEDs to signal the closing
of the contacts, the programming/cancellation condition
and the status of the controlled devices. The two LEDs
blink alternatively when the configurators are being read,
whereas when there is no configurator, only N1 blinks.
Configurators
There is also a local key for the virtual configuration
A PL1 PL2 M SPE
mode.
2)
2) according to the operating mode of the destination actuator.
NOTE:
If switches are connected to the interface terminals, the operating mode
to be selected is PUL.
If normally open (NO) pushbuttons are connected, all the other operating
modes shown in the table will be possible.
Configurator value in M
single function
double function
no
configurator
ON
1÷8
OFF
O/I
M
PUL

Publicité

loading