Milwaukee MXF500 Manuel De L'utilisateur page 5

Déboucheur électronique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ASSEMBLY
Recharge only with the charger
WARNING
specified for the battery. For spe-
cific charging instructions, read the operator's
manual supplied with your charger and battery.
Removing/Inserting the Battery
To remove the battery, push the battery latch to the
side and squeeze the battery latch lever. Pull the
battery pack away from the machine.
Always remove battery pack before
WARNING
changing or removing accessories.
To insert the battery, slide the pack into the body of
the machine. Make sure it latches securely into place.
Only use accessories specifically
WARNING
recommended for this machine.
Others may be hazardous.
Selecting the Proper Cable
Cat. No.
48-53-2325 5/8" x 25' Inner Core Drum Cable
48-53-2350 5/8" x 50' Inner Core Drum Cable
48-53-2310 5/8" x 100' Inner Core Drum Cable
48-53-2425 3/4" x 25' Inner Core Drum Cable
48-53-2450 3/4" x 50' Inner Core Drum Cable
48-53-2410 3/4" x 100' Inner Core Drum Cable
48-53-2905 3/4" Anchor Cable
48-53-2902 3/4" x 2' Leader Cable
48-53-2802 5/8" x 2' Leader Cable
Cable Attachments for 5/8" and 3/4" Cables
Cat. No.
48-53-2830 Straight Auger
48-53-2831 Funnel Auger
48-53-2832 3" Root Cutter
48-53-2833 4" Root Cutter
48-53-2834 6" Root Cutter
48-53-2835 Small Opening Tool
48-53-2836 Medium Opening Tool
48-53-2837 3" Grease Cutter
48-53-2838 4" Grease Cutter
48-53-2840 9 pc Head Attachment Kit
To prevent damage to the cable and
CAUTION
attachments, only use in recommended
pipe size.
Description
Description
Cable Installation
To reduce the risk of injury, always
WARNING
wear proper eye protection marked
to comply with ANSI Z87.1. Always wear leather
gloves over latex/rubber gloves to avoid entangle-
ment. Cable tip may be sharp. Never feed more than
100' of cable into the machine to avoid overloading.
Remove the cable for cleaning after each use. Differ-
ent size and types of cables are available for different
applications. The instructions below detail how to
remove/install the cable manually.
NOTE: The cable feed can also be used to advance/
retrieve the cable during installation (see "Using the
Cable Feed" in the Operation section).
To manually remove the cable:
1. Move the Forward/OFF/Reverse switch to OFF O
and remove the battery pack. Ensure the cable
feed is disengaged by pressing down on the
ratchet release button.
2. Pull the cable out through the nose of the drum
until the anchor cable shows.
3. Remove the cable from the anchor cable by insert-
ing the pin key into the coupling hole and pulling
the cable away.
4. To clean or maintain cable, follow the cleaning
instructions under "Maintenance".
To manually install the cable:
1. Move the Forward/OFF/Reverse switch to OFF O.
Ensure the cable feed is disengaged by pressing
down on the cable feed quick release button.
2. Attach the cable to the anchor cable by snapping
the attachment coupler into the cable coupler.
3. Move the Forward/OFF/Reverse switch to
Forward
.
4. Use the foot pedal to start the drum.
5. Manually feed the cable into the drum. WARNING!
Always wear leather gloves over latex/rubber gloves
to avoid entanglement.
Cable Attachment Installation
To install the attachment:
Snap the attachment coupler into the cable coupler.
Test the cable before inserting into the drain to make
sure the attachment does not fall off during use.
To remove the attachment:
Insert the pin key into the coupling hole and pull at-
tachment off of cable.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mxf501

Table des Matières