INSTALLATION INSTRUCTIONS
ATTENTION!
Please refer to the initial pages of this manual for the figures mentioned in this chapter.
APPLIANCE DESCRIPTION
Sturdy stainless steel structure with 4 adjustable feet
that can be adjusted in height. External coating made
in 18/10 chromium-nickel steel. The special steel plate
has a smooth or ribbed surface and pyroceram plates all
equipped with side and back steel splashguards. It is also
fitted with a stainless steel gravy collection tray. The steel
EN
plates are heated by armoured heating elements whilst the
pyroceram tops are heated by infrared heating elements.
Before initialising operation, remove all packaging. A
few pieces are protected by adhesive film, remove these
carefully.
If some glue remains on the surface, clean with suitable
substances, for example petrol, never use abrasive
substances. Assemble the feet of the appliance, the
appliance must be levelled; small levelling adjustments
may be made by regulating the feet. The main switch or
the socket must be close to the appliance and with easy
access.
The appliance should be installed under a range hood for
fast steam evacuation. Install the unit at least 5 cm from
the back and side walls (see Fig. 1).
The units whose the input tube of the power supply cord is
positioned on the back wall must be installed at least 5 cm
from the side walls (see Fig. 1).
Stand-alone units that weigh less than 40 kg must be
installed by means of the supplied kit in accordance with
the described method (see fig. 6).
Unscrew one of the legs and insert the pin in the largest
hole of the bracket "A", screw in the leg again and fix the
unit to the supporting surface with a "B" screw.
Room ventilation
The room where the appliance is installed, must be fitted
with air intakes to guarantee the correct operation of the
unit and air exchange.
The air intakes must have proper dimensions, be
protected by grids and they must be positioned free from
obstructions. (See Fig. 2 – Fig. 3).
PREPARATION
Caution – Warning
Do not install the appliance close to other units that
can reach high temperature: the electrical components
might be damaged.
During installation, make sure the air suction and
evacuation ways are free from any obstacles.
INSTALLATION
The appliance must be put in operation and serviced by a
qualified person.
All the installation works must be carried out according
to the regulations in force. The manufacturer declines any
responsibility in the event of wrong operation due to an
improper, or non compliant installation.
Warning!
Disconnect mains before any intervention.
For a direct network connection, it is necessary to
provide a device that ensures the disconnection
from the network with an opening distance from the
contacts that allows for a complete disconnection
under the conditions of overvoltage category III, in
accordance to the rules of installation.
If the power supply cord is damaged, have it cord
replaced by the manufacturer or their Technical
Assistance or by a qualified person.
Attention!
The yellow-green ground cable must never be broken.
ELECTRICAL CONNECTION
Connect the appliance to the mains as shown (see Fig.4
– Fig.5):
1) install, if not present, an isolator switch (A) close to the
appliance with an overcurrent trip and earth-leakage
contact breaker.
2) Open, if present, the doors (B) and loosen the screws
(C) to disassemble the panel (D).
3) Connect the isolator switch (A) to the terminal board
(H) as shown in the figures and in the electrical