TECHNICAL DATA

Dial Position
Range
Current AC
0.04A - 6A / 10A
Current DC
6 A / 10 A
600 mV / 6 V
Voltage AC
60 V / 600 V
600 mV / 6 V /
Voltage DC
60 V / 600 V
2Hz-99.99Hz/999.9Hz
Hertz
9.999kHz/50kHz
600 Ω / 6 kΩ / 60 kΩ
Resistance
600 kΩ / 6 MΩ
40 MΩ
Cont Buzzer
Continuity
0-600.0 Ω
Capacitance
100 μF / 1000 μF
These instruments are True-RMS sensing. All voltage and current readings are True-RMS values.
Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity
at 0 % to 85%.
Input impedance Voltage AC
Input impedance Voltage DC
Overload protection
Voltage DC, voltage AC, Hertz
Current DC & Current AC:
Resistance, Continuity, Capacitance
Maximum measurement time:
Minimum frquency measurement
Minimum AC Current measurement
For AC Voltage, AC Current:
Additional Accuracy by Crest Factor (C.F.):
Max. Crest Factor:
Measurement accuracy of square wave and
truncated waveforms at 1kHz is unspecified.
Maximum voltage between any terminal and earth ground
Temperature Operating
Temperature Storage
Temperature Coefficient
Operating Altitude
Battery
Battery run time
Weight according EPTA-Procedure 01/2003
Safety Compliance
Temperature Range, Resolution and Accuracy are for the instrument. Temperature Probe may have different
specifications.
26
ENGLISH
Resolution
Accuracy
0.001 A / 0.01 A
±(1.5% +3dgt) (45-500Hz)
0.001 A / 0.01 A
±(1.0% +3dgt)
0.1 mV / 0.001 V
±(1.0% +3dgt) (45-500Hz)
0.01 V / 0.1 V
±(2.0% + 3dgt) (500-1000Hz)
0.1 mV / 0.001 V
±(0.5% +2dgt)
0.01 V / 0.1 V
0.01 Hz / 0.1 Hz /
±(0.1% + 2dgt)
0.001 kHz / 0.01 kHz
Sensitivity: 10 Vp-p
0.1Ω / 0.001kΩ / 0.01kΩ
±(1.0% +5dgt)
0.1kΩ / 0.001 MΩ
±(1.0% +5dgt)
0.01 MΩ
±(2.0% +5dgt)
0.1 Ω
Beeper sounds at 30Ω and below
0.1 μF / 1 μF
±(1.9% +2dgt)
AC/DC 720V for 10 second
AC/DC 20A for 10 sec.
AC/DC 600V for 10 second
1 minute at 10A, rest time 20 minutes minimum
1.0% for C.F within 1.4-2.0; 2.5% for C.F within 2.0-2.5; 4.0% for C.F. within 2.5-3.0
1.6 for 6600 ~ 5000 digits,2.0 for 5000 ~ 3000 digits, 3.0 for 3000 ~ 0 digits
0. 1 x specified accuracy /°C (<18°C or >28°C)
about 30 h with all functions
CAN/CSA C22.2 NO.61010.1-2004; UL61010-1-2004;
IEC/EN61010-1 2nd Edition;
WARNING! Read all safety warnings and all
instructions, including those given in the
accompanying brochure. Failure to follow the
warnings and instructions may result in electric shock,
fire and/or serious injury.
Save all warnings and instructions for future
reference.
SAFETY INSTRUCTIONS Measuring Instrument
Never make measurement on a circuit in which voltage
over 600 V exists. Use only leads rated 600 V or better.
Keep fingers away from test tips during measurements.
To reduce the risk of electric shock for Resistance,
Continuity, and Capacitance measurements, never use the
meter on an energized circuit. Make sure a capacitor is
fully discharged before touching or attempting to make a
measurement.
Do not attempt to make measurement in the presence of
flammable gases. Otherwise, the use of the instrument
may cause sparking, which can lead to an explosion.
Never attempt to use the instrument if its surface or your
hand is wet.
Do not exceed the maximum allowable input of any
measuring range.
Only test on unenergized circuits unless absolutely
10 MΩ / < 100 pF
necessary.
10 MΩ
Check tool functionality on a known circuit first.Never
assume tool is working. Assume circuits are live until
they can be proven de-energized.
Do not ground yourself while measuring. Avoid body
contact with earthed or grounded surfaces such as pipes,
radiators, ranges and refrigerators.
2Hz
Never remove the case or battery cover during a
0.040A
measurement.
This instrument is to be used only in its intended
applications or conditions. Otherwise, the instrument's
safety functions may not work, resulting in serious personal
injury and instrument damage.
To reduce the risk of injury from shock and arc blasts,
600 V
always wear personal protective equipment where live
-10°C - 50°C
conductors are exposed.
-40°C - 60°C
Never attempt to make measurement if any abnormal
conditions, such as broken case and exposed metal parts
are found on the instrument.
2000 m
Do not rotate the Rotary Dial while the test leads are being
2 AA
connected.
Do not install substitute parts or make any modification to
365 g
the instrument. For repair or re-calibration, return the tool
to a factory Service/Sales Support Branch or authorized
service station.
Category III 600V;
Only use Milwaukee test leads with this Milwaukee digital
Pollution Degree 2;
multimeter. Inspect test leads before each use. Use the
EMC EN61326-1
continuity function of this digital multimeter to run a
continuity test.
Measurement categories and their significance
according to IEC 61010-1:
CAT III: Measurements in the building installation:
stationary loads, distribution board, device firmly on the
distribution board.
SAFETY INSTRUCTIONS Battery
This tool is designed to be powered by 2 AA batteries
properly inserted into the instrument. Do not attempt to
use with any other voltage or power supply.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands
(or types within brands) of batteries.
Do not mix rechargeable and non-rechargeable
batteries.
Install batteries according to polarity (+ / –) diagrams.
Properly dispose of used batteries immediately.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least
10 minutes and immediately seek medical attention.
This appliance is not intended for use by persons (including
children) with limited physical, sensory or mental
capabilities or insufficient experience and/or knowledge
unless they are supervised by a person who is responsible
for their safety or have been instructed by them in the safe
use of the tool.
Children should be supervised in order to ensure that they
do not play with the tool.

SPECIFIED CONDITIONS OF USE

The Measuring Instrument may be used for following
measurements: Current AC, Current DC, Voltage AC,
Voltage DC, Frequency, Resistance, Continuity,
Capacitance. This instrument may only use for measuring
the previously indicated measurements.

SLEEP FUNCTION

The instrument is automatically powered off in about 20
min after the last Rotary Dial or button operation. To
reset, rotate the Rotary Dial to OFF. If the display is still
blank when a new dial setting is selected, replace the
batteries. The instrument does use battery power in
sleep mode. Be sure to switch the tool to OFF to
conserve battery power.
WORKING TIPS
Set the Rotary Dial to an appropriate position before
starting measurement.
Firmly insert the test leads.
Do not expose the instrument to the direct sun, high
temperature and humidity or dew fall.
Altitude 2000 m or less. Appropriate operating
temperature is within -10ºC and 50ºC.
The IP rate of the instrument is IP54, use it accordingly.
Be sure to power off the instrument after use. When the
instrument will not be in use for a long period, place it in
storage after removing the battery.
Use a damp cloth or neutral detergent for cleaning the
instrument. Do not use abrasives or solvents.
MAINTENANCE
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service
addresses).
If needed, an exploded view of the tool can be ordered.
Please state the Article No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
ENGLISH
27

Publicité

Table des Matières
loading

Table des Matières