ChargiNg phases

the concept of the charging process is explained based on a 12 V battery.
V
A
1
2
Diagnosis
diagnostic function which automatically checks the battery status and recognises the
voltage.
Voltage
0 V to 1.5 V
1.5 V to 12 V
12 V to 13 V
14.6 V
>15 V
Step 1: Condition check
the charger checks the battery condition and calculates the required
charging parameters.
Step 2: Desulphation (rescue)
the charger can rescue most drained batteries with voltages up to a minimum of
1.5 ±0.5 V.
the safety switch does not allow the charger to start charging if the voltage is
below 1.5 ± 0.5 V.
3
4
Function
"error" Led (9) lit. Battery defective.
Charging starts.
Maintenance charging starts.
Battery fully charged. "Full" Led (10) lit.
"error" Led (9) lit.
5
6
GB
37
7
8

Publicité