N o s e A s s e m b l i e s
F i t t i n g I n s t r u c t i o n s M a x l o k
Air supply must be disconnected when fitting or removing nose assemblies
Fit Locking Ring 8 onto the Chuck Collet Adaptor.
Lightly coat Jaws 4 with Moly Lithium grease.
Drop Jaws 4 into Chuck Collet 9.
Insert one Spring Guide 10 into Chuck Collet 9.
Locate Spring 7 onto the Spring Guide 10 already in place.
Drop the other Spring Guide 10 into Spring 7.
Holding tool pointing down, screw the assembled Chuck Collet onto the Chuck Collet Adaptor and tighten with spanner.
Screw Anvil Adaptor 15 into the Head Assembly.
Place Anvil 12 over Chuck Collet 9 and lock into place with Anvil Nut 16.
15
8
S e r v i c i n g I n s t r u c t i o n s
Remove nose assembly from tool using the reverse procedure to the fitting instructions above.
Clean parts. Worn or damaged parts should be replaced.
Check the Anvil 12 for wear and/or damage to the swaging bore.
Lightly coat Chuck Jaws 4 and Chuck Collet 9 internal bores with Molylithium grease.
Assemble as above instructions.
Item numbers in bold refer to the Maxlok
10
®
I M P O R T A N T
10
7
10
4
®
Nose Assembly on page 8.
9
12
16