Installation; Built-In Installation Single Appliance - Fulgor Milano F7PBM36S1-L Notice D'installation

Masquer les pouces Voir aussi pour F7PBM36S1-L:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Installation

EN
IMPORTANT
The following instruction for installation apply to all models.

6.1 Built-in installation single appliance

For a built-in installation, to cover gaps between the
appliance and the adjacent cabinets, special side profiles
and aluminum covering frames are already factory installed.
Operate as follows:
• Push the appliance into the installation niche [ 1 ].
1
• If the unit is to be installed inside a niche or within an
enclosed structure, it is necessary to provide air flow
at the back of the niche to assure proper ventilation at
the back of the unit. A 5 mm gap is sufficient to prevent
overheating. Always mount front panels on door and
drawer before pushing the unit into its final position
inside the niche or structure.
• Check the levelling of the appliance, adjusting its feet
and wheels to correct it.
• Secure the appliance to the adjacent cabinets by fixing to
these the side profiles factory-installed on the appliance
[ 2 ].
To make this operation easier keep the door and the
drawer open.
2
18
• Mount the profiles the
laterally and then push firmly until a "click" is heard [ 3 ].
3
Side profiles mounting:
6,5 (¼")
Appliance
22 ( ⁄ ")
Wall or furniture
A - Profile connection trim (screws for fixing to cabinetry not
included)
B - Profile trim cover
trim covers: first insert them
6,5 (¼")
A
B
22 ( ⁄ ")

Publicité

Table des Matières
loading

Table des Matières