5.3
Mounting the pressure line
A. Unitop
B. Condensate trap
If no connection thread is available on the tank, several lines can be con-
nected via the combination fitting "Euroflex 3" to a single G1 connection
thread.
1. Mount the vertical line in the tank in such a way that the lower end of the
vertical line is approximately 20 mm above the lowest point of the tank
bottom.
2. Install the measuring line with a steady gradient towards the tank, avoid
bends.
3. Push the screw connection onto the measuring line.
Mounting
E
D
C
C. Bottom part
D. Standpipe
E. Measuring line
A
Unitop
EN
B
14

Publicité