memorisation of transmitters not belonging to the system. To
enable/disable this function, proceed as follows:
01. Press and hold P1 to power up the receiver and wait for
Led L1 to emit first the signals as specified in chapter
5.1; then ensure that it emits 2 quick orange flashes (=
procedure activated) and lastly that it indicates the colour
corresponding to the current enable status. Then release
the key.
02. Within 5 seconds, repeatedly press the receiver key to
select one of the following functions:
• Led OFF = No lock enabled
• Led GREEN = Memorisation "in the vicinity" locked
• Led RED = Memorisation with "enable code" locked
• Led ORANGE = Both memorisation modes locked ("in
the vicinity" and with "enable code")
03. Within 5 seconds, press any key of a transmitter already
memorised on the receiver to save the selected function.
• ENABLING (or disabling) THE RECEIVER FOR
MEMORISATION OF A TRANSMITTER USING
THE RECEIVER "CERTIFICATE NUMBER"
[with Obox (OX4T ONLY)]
This function is used to enable/disable the option on the
re ceiver for memorising a transmitter by means of the receiver
cer tificate number.
For further information on the use of the certificate, refer to
the instruction manual of the transmitter and the NiceOpera
System Book.
• ENABLING (or disabling) UPDATES TO THE
TRANSMITTER PRIORITY STATUS
[with Obox (OX4T ONLY)]
This function is used to enable/disable the option on the
re ceiver for updating the priority level of the previously
memori sed transmitter in the NiceOne series to a higher level.
This function is enabled by default. For further information on
managing priority, refer to the instruction manual of Obox and
the NiceOpera System Book.
• ENABLING (or disabling) RECEPTION OF NON-
ORIGINAL TRANSMITTER "IDENTITY CODES"
[with Obox (OX4T ONLY)]
This function is used to enable/disable the option on the
receiver to accept the command received from a transmitter
with an identity code that has been modified with respect to
the original factory setting. This function is enabled by default.
For further information on modifying transmitter identity co des,
refer to the instruction manual of Obox.
• ENABLING (or disabling) MANAGEMENT OF
ROLLING CODE (RND)
[with Obox (OX4T ONLY) and Oview]
This function is used to enable/disable the receiver for man-
agement of the variable section (rolling code) of an identity
code sent by a transmitter. When this function is active, the
receiver treats a "rolling code" as if it were a "fixed" code, igno-
ring the variable section This function is disabled by default.
EN