Turning off the device
1. Close the gas supply at the gas cylinder.
2. Turn the thermostat (3) to the  position.
7.5
Positioning the shelves
➤ Proceed as shown to position the shelves (fig. 8, page 8).
7.6
Locking the door
➤ Proceed as shown to unlock the door (fig. 9, page 8).
➤ Proceed as shown to lock the door for transport (fig. 0, page 9).
7.7
Defrosting the device
A
NOTICE! Damage hazard
• Never use mechanical tools to remove ice or to loosen objects stuck
to the device.
• Never use heated devices or heaters to speed up the defrosting pro-
cess.
I
NOTE
Over time, frost builds up on the cooling fins inside the device. If this
layer of frost is about 5 mm thick, you should defrost the device.
1. Disconnect the voltage and gas supply.
2. Empty the device.
3. Put a cloth in the compartment to absorb any excess water.
4. Leave the door open.
5. Wipe the compartment dry with a cloth.
7.8
Switching off and storing the device
If you intend to not use the device for a longer period, proceed as follows:
1. Disconnect the voltage and gas supply.
2. Clean the device (see chapter "Cleaning and maintenance" on page 47).
3. Set the door lock in the ventilation position (fig. a, page 9) to prevent odors
from forming.
46
8

Cleaning and maintenance

!
WARNING! Electrocution hazard/Fire hazard
• Always disconnect the device from the mains before you clean and
service it.
• Repair work and maintenance work on the cooling aggregate and
the gas burner system may only be carried out by an authorized
repair center.
A
NOTICE! Damage hazard
Never use sharp cleaning agents or hard or pointed tools to remove ice
or to loosen objects which have frozen in place.
➤ Clean the device regularly and as soon as it becomes dirty with a damp cloth.
➤ Make sure that no water drips into the seals. This can damage the electronics.
➤ Wipe the device dry with a cloth after cleaning.
➤ Check the condensate drain regularly.
Clean the condensate drain when necessary. If it is blocked, the condensate
collects on the bottom of the device.
Changing the gas filter
➤ Proceed as shown to change the gas filter (fig. b, page 10).
Replacing the ignition battery
➤ Proceed as shown to replace the ignition battery (fig. c, page 11).
9

Troubleshooting

Problem
Possible cause
The device does not
The device has not
work.
been set up properly.
The refrigerant circuit is
defective.
GB
Suggested remedy
Check if the device is horizontal.
Check if the ventilation of the device is
sufficient.
This can only be repaired by an
authorized repair center.