No.in
Explanation
fig. 1, page 4
5
Door inserts
6
Freezer (only RF62)
5.2
Operating panel
No.in
Description
fig. 2, page 4
1
Energy selector switch
2
Flame indicator
3
Thermostat
4
Ignition button
Energy selector switch
Symbol
Description
fig. 2, page 4
Off
AC operation
DC operation
Gas operation
6

Placing and connecting the device

6.1
Instructions for placing the device
Observe the following when placing the device:
• Maintain at least 10 mm clearance to the walls.
• Keep the ventilation openings clear of all obstructions to ensure a good
ventilation.
➤ Place the device on a level surface. Use a water level to check this.
40
6.2
Changing the door hinge
!
WARNING! Electrocution hazard
Before performing any work on the device, unplug the power plug.
You can change the hinge of the door, so that it opens to the left rather than the right.
➤ Proceed as shown to change the door hinge (fig. 3, page 5 to fig. 4, page 5).
6.3
Replacing the door panel
!
WARNING! Electrocution hazard
Before performing any work on the device, unplug the power plug.
➤ Proceed as shown to replace the door panel (fig. 5, page 5).
6.4
Connecting to an AC supply
1. Check that the voltage specification on the type plate is the same as that of the
power supply.
2. Plug the AC connection cable into the AC mains.
6.5
Connecting to a DC supply
A
NOTICE! Damage hazard
• Make sure the polarity is correct when connecting to a terminal.
• To avoid voltage drops and loss of performance, keep the cable as
short as possible and avoid joins. For this reason avoid additional
switches, plugs or multi-way adapters.
• Disconnect the device and other electric loads from the battery
before connecting the battery to a quick charging device. Over-
voltage can damage the electronics of the device.
• Fit a fuse of at least 15 A to the positive connection.
• If you connect the device to the vehicle power, remember that you
may have to turn on the ignition to supply it with power.
1. Check that the voltage specification on the type plate is the same as the battery
voltage.
2. Determine the required cross section of the cable in relation to the cable length
according to the following table:
GB