Maintenance; Decommissioning; Spare Parts Service; Warranty Conditions - Schneider Airsystems KNG 40 SYS Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
4. Place the trigger safety device (item 06)
or guide plate (item 07) onto the work-
piece and apply pressure firmly.
5. Press the trigger lever (item 02).
After use:
1. If available:
Secure the interlock (item 10).
2. Disconnect the quick-action coupling
from
the
plug
(Figure 1b).
3. Empty the magazine (item 04).
4. Clean the device dry with compressed
air.
5. Store the device in a secure location.
2.5

Maintenance

Regular lubrication is required!
Oil using a maintenance unit
with filter pressure reducer and mist oiler.
Add oil manually into the
plug nipple (item 01).
For long breaks in operation, also oil via
plug nipple (item 01) using special oil for
compressed air tools.
2.6

Decommissioning

Storage: Clean, dry, dust-free, not below
5° C.
2.9

Troubleshooting

Observe the safety instructions and maintenance instructions!
Problem
A
Device does not
function
B
Compressed air
escaping from the
opening on the
cover
nipple
(item 01)
Cause
Trigger lever (item 02) secured
with interlock (item 10)
Working pressure (flow pressure)
too low
O-ring or seal damaged or dirty
Disposal: Dispose of the packaging / device
/ materials used according to applicable legal
regulations.
2.7

Spare parts service

Visit
our
website
tems.com/td/ for the latest version of all ex-
ploded drawings and spare parts lists for our
products. If you have any special questions,
please consult the Schneider Airsystems Ser-
vice centre in your country (addresses in the
service appendix) or your local dealer.
2.8

Warranty conditions

Basis for warranty claims: complete unit
in original condition/proof of purchase.
According to legal provisions, you re-
ceive the following warranty against
material and manufacturing defects:
private use only: 2 years,
commercial use: 1 year.
Excluded from warranty claims: Wear or
expendable parts, improper use, overloading
/ incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.
Remedy
Unlock
(item 02) (Fig. 4a)
Increase working pressure
(flow
maximum
sure
Contact Schneider Druckluft
GmbH or an authorised ser-
vice partner.
KLG / KNG / SNG
www.schneider-airsys-
the
trigger
pressure)
Observe
working
pres-
*
****
GB
lever
II/ 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

D300044

Table des Matières